Tianjin TAIYITO Technology Co., Ltd 

taiyito

Home > Products > Intelligent Community > Smarthome Indoor Gateway

    TDWZ6619--HL Smarthome Indoor Gateway

    • No.: TYTVST(IOS) TYTSmart (Android)
    • Brand :
    • Weight:

    TDWZ6619--HLFeatures (this product has been increased partial hardware Circuit, it also can be as a Intelligent home gateway after upgraded ) Simple and stylish,  silver / gold acrylic panel

    1. Detailed information

    TDWZ6619--HL  Smarthome Indoor Gateway

    TDZ-HL 450X300.jpg


    可视对讲全系统--泰益通标.png

    Features (this product has been increased partial hardware Circuit, it also can become one of Intelligent home gateway of zigbee system after upgraded )

     

    Simple and stylish,  silver / gold acrylic panelhas always been the pursuit of simple, low-key highlight in the noble style of luxury.

     

    The Digital Intelligent video intercom systemadopts standard TCP / IP transport protocol, Network architecture using three layer switch-based network (LAN) transmission technology.  Multi channel intercom at the same time can be allowed for this system, and there is alarm recording and alarm recording process management window on Operty Management Center Computer.

    The Indoor Terminal User Manual adopts 7 inch Digital liquid crystal LED Touch Screen.

     

    For Publish information, The outdoor terminal can be used to broadcast audible videos or pictures, such as advertisement ;

    Also the system supporting Households call Talkback ;

    The Indoor Terminal User Manual also integrated security system, It has 8 defense security interface:  0ne click deployment, password removal, tamper alarm ;

            Emergency button ;

    Video message ;

    Monitoring unit door machine and wall door video ;

    Change display background ;

    Owners leaving message function ;

    Capturing real-time images ;

    Has the ability to support multi-channel management ;

    Clear voice calls, communication and stability ;

    Record calls function ;

    You can enjoy Pixel display GIF,  Clear and bright picture quality, with Weak light compensation function and Strong inhibition function ;

    Software Automatic Update...

     

    Ø  Technical Parmeter

           Installation:  Wall type (depending on the specific mold)

    Display     7″ TFT LCD (colour)

    Touchscreen:  High precision Four-wire resistance touch-screen

    Resolution 800×480

    Bell       Electronic bell≥70dB

    Power     DC 12V/1A

    Working electrical current < 300mA

    Working temperature     -20ºC ~ +70ºC

    The Maximum power     < 3.6W

    Outlook size             139H mm×245W mm×21D mm 

     

    Ø  Visual intercom

    Indoor terminal device could "accept" the visual call from outdoor, wall, management and other network terminal,could call all same type terminals and the management terminal under system with two-way visual intercom.

    Ø  Remote unlock/lock

    Indoor terminal device has "unlock" function button, you could unlock/lock the gate door, house or anywhere has a electric door lock under the system.

    Ø  Monitor control

    Indoor terminal device could control outdoor terminal/wall camera to monitor the gate area or the surrounding environment, and could monitor the linkage of the camera system.

    Ø  Leave message

    When user leaves home, the terminal device could set"answer"to "leave message", for leaving message from visitors.

    Ø  Community call

    Terminal device could video/call each other in the same community.

    Ø  Call log

    Terminal device could automatically record the missed calls, received calls and dialed calls and other messages, and display the standard recording time, for the query at any time.

    Ø  Smart home 

    Terminal device could control the home appliances, external intelligent switch, works with a variety of scene modes. Specific functions for Smart Community Indoor panel please refer to the related products in Smart home, such as the Gateway TDWZ6617 and other products work with it. 


     Home security alarm

    Terminal device could set extension standoff module, one button swith on/off,  or a password swith. System with forced password disarm/alarm function, when it is on a non voluntary disarming, system send the alarm code to the management center.Indoor terminal can be connected with the infrared, emergency button, smoke, gas sensor, etc. and control not less than 8 standoff areas.

     Status detection

    The user terminal could state detection function to check the working status of standoff probe, it is convenient and quick

    Ø  Fast selftest

    Fast expolre the configure information of the terminal, such as the specific distribution of the network IP, room number and system version. To provide convenience support for the installation and maintenance of the project.

    Automatically upgrade

    Information terminal equipment system automatically detects the latest software version, and automatically update.


    2009-Z数字联网布线拜拓朴图--泰益通--900-1000.jpg

    Chapter 1 Press Button of Indoor Unit

    Running the same operating system, there are multiple models for indoor unit options. 

    Tips:

    Power LED:Light on --- Device is powered on.

    Mute Key:witch between MUTE and VOICE.

    Monitor Key:Monitor the outdoor station.

    Unlock Key:When visitors call, press unlock key. And it is also the Return key.

    Call Key:When visitors call, press call key and talk back. 


    Chapter 2  Sign Symbol of Indoor Unit

    At the top of UI, several sign symbols represent different status of Indoor Unit:


    Symbol
    Item
    Representation

    Tianjin TAIYITO Technology Co., Ltd

        Unarmed Status    IR sensors or Door/Window contacts are off. 

    Tianjin TAIYITO Technology Co., Ltd

        Night Status    All sensors/detectors are on in specific period at night.
    Tianjin TAIYITO Technology Co., Ltd
        Home Status    All sensors/detectors are on in specific period in daytime.
    Tianjin TAIYITO Technology Co., Ltd
        Away Status    All sensors/detectors are on in specific period when you are out of the house.
    Tianjin TAIYITO Technology Co., Ltd
        Community News    Incoming unread community news.
    Tianjin TAIYITO Technology Co., Ltd
        Missing Call    Missing call.
    Tianjin TAIYITO Technology Co., Ltd
        Leaving Msg    Unread Message/Recoding
    Tianjin TAIYITO Technology Co., Ltd
        Network Connected    Successfully connect to the network..
    Tianjin TAIYITO Technology Co., Ltd
        Network Disconnected      Fail to connect to the network.
    Tianjin TAIYITO Technology Co., Ltd
        Mute Status    The ringtone is mute.


    Chapter 3  Basic Operation

    1 Home Page

    Picture 2 is the Home Page of Indoor Unit.


    picture2.png

    Picture 2


    Demonstration:

    1). On the left side of UI, there are 8 main functions, including,

    Smart Home; Record Center; Household Security Protection; Monitor; Video Intercom; User Setting; System Setting..

    2). On the right side of UI, there are 6 shortcut menu, including,

    Turn off ringtone; Call elevator; Building Monitor; Call Center; Community News; Set armed status.

    2 Operation of Basic Function

     In Picture 2, Click the sign symbol “Video Intercom” and then refer to the Picture 3.


    picture3.png

    Picture 3


    Inter-dialing: 1. A key pad will be shown in the UI. Enter specific room number to call. Not support to call your own room number and the UI will present “The room number you dialed cannot be connected.”

    Inner-dialing: Enter Indoor Unit Number to call other indoor units in your own house.

    Call Center: Call to Guard Station or Computer Administration Center. If there are several indoor units calling to Guard Station, Guard Station device will receive calls and ring at the same time.

    Telephone Directory: Functions include Add/Delete contactor; turn to former/next page; and call.

    In Picture 3, click “Inter-dialing” to dial room number. Please refer to Picture 3-1.


    picture3-1.png

    Picture 3-1


    During call, a UI will be shown. Please see Picture 3-2.


    picture3-2.png

    Picture 3-2


    Inter-dialing: 1. Key pad (Picture 3-1). Enter specific Room Number to call (Picture 3-2). Not support to call your own room number and the UI will present “The room number you dialed cannot be connected.” If there are several indoor units in a house, you may need inner-dialing function --- Enter Indoor Unit number to call other devisions.

    In Picture 3, click “Telephone Directory” to call. Please see Picture 3-3.


    picture3-3.png

    Picture 3-3


    Telephone Directory: 

    Functions include Add/Delete contactor; turn to former/next page; and call.

    If click “Call Center”, you will see a UI referring to Picture 3-4.


    picture3-4.png

    Picture 3-4


    Indoor Unit will automatically call to Guard Station or Computer Administration Center. If there are several indoor units calling to Guard Station, Guard Station device will receive calls and ring at the same time.

    2.2 Monitor

    In picture 1, click “Monitor”. Please refer to Picture 4.


    picture4.png

    Picture 4


    The UI will present different items for options. Monitor the camera you want to see by clicking on the relative icon. 

    Network Camera: Engineers will add the devices you have in the Engineering Setting (Entering the IP address). Every camera support taking pictures for record.

    In Picture 4, click “Camera NO.1”. Then see the Picture 4-1.


    picture4-1.png

    Picture 4-1


    2.3 Information Center (Community News & Record Center)

           2.3.1 Community News

    In Picture 2, click “Community News”. Then see the Picture 3.1-1.


    picture3.1-1.png

    Picture 3.1-1


    In the UI of “Community News”, functions include record personal information; turn page; check and delete, etc.

           2.3.2 Record Center

    In Picture 3-1, click “Record Center”. Then refer to Picture 3.2-1.


    picture3.2-1.png

    Picture 3.2-1


    Community News: Store community news from administration center.

    Security Protection Record: List all records of users’ operation.

    Alarm Record: List all records of indoor unit’s alarming status.

    Photo Record: List all records of taking photos automatically when monitoring.

    Calling Record: List all records of received/ missing/ dialed callings.

    Visitors’ Leaving Photo: When visitors call indoor unit, camera will capture a photo automatically and send and store it to indoor unit. It can only store 10 pcs of photos at maximum.

    Visitors’ Leaving Msg.: When the calling ends and no one receives call from indoor unit, outdoor station will tip --- Please press # key once then leave your message after hearing a sound DI. If visitors did not press # key, after 10 seconds, outdoor station will turn down this function. Time period of leaving message is 30 seconds. Photos when visitors leaving message will be stored in record. It can only store 10 pcs of photos at maximum. Once over 10 pcs, the new record will cover the former ones.


    picture3.2-2.png

    Picture 3.2-2 (The same as Picture 3.1-1)

    Community News: Store news released from administration center. Please refer to Picture 3.2-2. 

    1.Personal information: When administration center releases personal information, indoor units can immediately receive. (ONLY support files in form of JPG.)

    2.Public information: When administration center releases public information, indoor units can simultaneously and automatically receive. (ONLY support files in form of JPG.) 

    3.Maximum capacity is the latest 30 pcs records. Once over 30, it will cover the former ones.


    picture3.2-3.png

    Picture 3.2-3

    Security Protection Record:

    List all records of users’ operation. Please see Picture 3.2-3.


    picture3.2-4.png

    Picture 3.2-4

    Alarm Record: List all records of indoor unit’s alarming status. Please see Picture 3.2-4.


    picture3.2-5.png

    Picture 3.2-5

    Photo Record: List all records of taking photos automatically when monitoring. Please refer to Picture 3.2-5.


    picture3.2-6.png

    Picture 3.2-6

    Calling Record: List all records of received/ missing/ dialed callings. Please refer to Picture 3.2-6.


    picture3.2-7.png

    Picture 3.2-7

    Visitors’ Leaving Photo: When visitors call indoor unit, camera will capture a photo automatically and send and store it to indoor unit. It can only store 10 pcs of photos at maximum.

    Visitors’ Leaving Msg.: When the calling ends and no one receives call from indoor unit, outdoor station will tip --- Please press # key once then leave your message after hearing a sound DI. If visitors did not press # key, after 10 seconds, outdoor station will turn down this function. Time period of leaving message is 30 seconds. Photos when visitors leaving message will be stored in record. It can only store 10 pcs of photos at maximum. Once over 10 pcs, the new record will cover the former ones.

    2.4 Household Security Protection

    In Picture 2, click “Household Security Protection” and then see Picture 4-1.


    picture4-1h.png

    Picture 4-1


    1). Click “Armed” to enter into process of counting down. When time out, it successfully sets armed.

    2). Click “Unarmed” and enter the unarmed code. 

    If the code you entered is the “Kidnapped Code”, it superficially showed that system was unarmed and would not alarm. But actually indoor unit has already called Guard Station to ask for help and the “Unarmed” instruction would not be sent out.

    2.5 User Setting

    In Picture 2, click “User Setting” icon and refer to Picture 5-1.


    picture5.png

    Picture 5


    System Information: room number; IP address code; subnet mask; gateway; network configuration table; program version; manufacturer information.

    Ringtone Setting: Indoor unit ringtone options. Support external Flash and SD card.

    Screensaver Setting: black/clock/time screensaver options.

    Time Setting: Support setting year/month/day, hour/minute/second. 24-hour clock. 

    Password Setting: No initial code. User can set password freely. After entering a new password twice, an unlock password has been formed. Kidnapped Code is the reversed version of password. For example, enter “1234” as password; then “4321” is Kidnapped Code. Both of these 2 passwords can release the door. BUT the difference is when user enter the Kidnapped Code to open the door, it will not alarm but indoor unit will call to Guard Station automatically without tips.

    Volume Setting: Set volume when ring/ press/ call.

    Wallpaper Setting: Multiple wallpaper options.

    Delaying Setting: When set armed status, the delaying time is 60s with the optional range of 30~99s. Screensaver delaying time is 60s. Being called delaying time is 30s. Alarm delaying time is 60s. The continuous ringtone delaying time of alarm is 5 min. 

    In Picture 5, click “System Information” and refer to Picture 5.1-1: room number; IP address code; subnet mask; gateway; network configuration table; program version; manufacturer information.


    picture5.1-1.png

    Picture 5.1-1


    In Picture 5, click “Ringtone Setting” and refer to Picture 5.1-2: Indoor unit ringtone options. Support external Flash and SD card.


    picture5.1-2.png

    Picture 5.1-2


    In Picture 5, click “Screensavers Setting” and refer to Picture 5.1-3: black/clock/time screensaver options.


    picture5.1-3.png

    Picture 5.1-3


    In Picture 5, click “Time Setting” and refer to Picture 5.1-4: Support setting year/month/day, hour/minute/second. 24-hour clock. 


    picture5.1-4.png

    Picture 5.1-4


    In Picture 5, click “Password Setting” and refer to Picture 5.1-5: No initial code. User can set password freely. After entering a new password twice, an unlock password has been formed. Kidnapped Code is the reversed version of password. For example, enter “1234” as password; then “4321” is Kidnapped Code. Both of these 2 passwords can release the door. BUT the difference is when user enter the Kidnapped Code to open the door, it will not alarm but indoor unit will call to Guard Station automatically without tips.


    picture5.1-5.png

    Picture 5.1-5


    In Picture 5, click “Volume Setting” and refer to Picture 5.1-6: Set volume when ring/ press/ call. When volume is set as “0”, on the top of UI, there will be an icon , which represents MUTE. 

    2.6 System Setting

    In Picture 2, click “System Setting” and refer to Picture 6-1.


    picture6-1.png

    Picture 6-1


    1).Security Protection Setting: what/ where the detectors/sensors are. Whether to use detectors/sensors (Emergency, Smoke, Gas sensors are turned on all the time. Once it alarms, no tips on indoor units but directly call to Guard Station.)

    2).Room Number Setting: Set indoor unit code based on the network configuration table.

    3).Outdoor Station Setting: set the current use of indoor machine network configuration table in any of the indoor coding.

    4).Engineering Code: Enter 6-digit former code (The default code is 123456). By entering the same code twice to set a new engineering code.

    5).System Reset: When user needs to reset all settings, e.g.: room number, all password and code, and other settings.

    6).Network Camera: After adding the camera IP address code into indoor units, user can directly monitor different cameras by a click. 

    In Picture 6-1, click “Room Number Setting” and refer to Picture 6.1-1. Set indoor unit code based on the network configuration table.


    picture6.1-1.png

    Picture 6.1-1


    In Picture 6-1, click “Outdoor Station Setting” and refer to Picture 6.1-2. set the current use of indoor machine network configuration table in any of the indoor coding.


    picture6.1-2.png

    Picture 6.1-2


    In Picture 6-1, click “Engineering Code” and refer to Picture 6.1-3. The default code is 123456.


    picture6.1-3.png

    Picture 6.1-3


    In Picture 6-1, click “System Reset” and refer to Picture 6.1-4.


    picture6.1-4.png

    Picture 6.1-4


    In Picture 6-1, click “Network Camera” and refer to Picture 6.1-5.Z


    picture6.1-5.png

    Picture 6.1-5


    After adding the camera IP address code into indoor units, user can directly monitor different cameras by a click. 

    2.7 Smart Home

    In Picture 2, click “Smart Home” and refer to Picture 7-1.


    picture7-1.png

    Picture 7-1


    External light-controlled intelligent switch/ curtain controller/ intelligent socket.

    Home automation controlling Module, including sleeping mode, all-off mode, entertainment mode, at-home mode, picnic mode, and movie mode, etc.

    If needs to connect with external intelligent switch, the in-house diagram is as below:


    tuopu.png


    2.8 Call Elevator

    In Picture 2, click “Call Elevator” and refer to Picture 8-1. 


    picture8-1.png

    Picture 8-1


    2.9 Initial Code Chart

    Code Chart


    ItemInitial CodeChanged Code
                Outdoor Station Password for Unlock888888
                Outdoor Station Engineering Code666666
               Outdoor Station Kidnapped Code for Unlock (Public Use)543210
                 Indoor Unit Unarmed Code123456
                Kidnapped Unarmed Code for User Use654321
                 Indoor Unit System Setting Code123456
                 Indoor Unit User Setting Code666666


    TDWZ6619  Installation diagram.jpg





    Powered by taiyito  ©2005-2017 www.taiyito.com